Showing results: 91 - 105 of 128 items found.
-
PRPDreplay -
Power Diagnostix Systems GmbH
The compact PRPDreplay is easy to use and the ideal solution for all situations in which partial discharge pulses are required but no PD source is available. The portable instrument is therefore suitable for use e. g. in research, education, and training as well as for sensitivity or PD instrument checks.
-
Power Diagnostix Systems GmbH
Partial discharge monitoring systems can be used for permanent surveillance of insulation systems on GIS, transformers, rotating machines, motors, cables, or other high voltage equipment. These instruments are designed for long term data recording, alarm handling, event recognition, and system integration.
-
HFCT-20HD & HFCT-60HD™ -
ndb Technologies Inc.
The HFCT-20HD™ and HFCT-60HD™ are high frequency current transformer sensors designed for partial discharge detection on electric apparatus’ ground returns. Made from superior quality materials, it is designed for any environment.
-
TD 100 -
Scope T&M Pvt, Ltd.
TD100 is an innovative NDT - Non-Destructive Testing equipment, which detects, pinpoints and documents flash-arc corona and arcing partial discharge camera. Being with high sensitivity, it is a power tool to detect UV emission in full daylight with high signals from faraway and nearby sources.
-
Power Diagnostix Systems GmbH
This group of instruments offer partial discharge measurement functions of different performance level. Devices for test and research laboratories as well as systems for on-site PD analysis are available. Stand alone units, computer controlled systems or wireless operating acquisition sets are shown in this area.
-
Liona -
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR liona. Liona is a portable online PD spot tester for measuring and locating partial discharges in cables and switchgear during normal mains operation. Liona lets you test cable systems and electrical equipment online without switching off partial discharge activities, and then generate trend analyses. Even a PD spot test (duration: 5-10 minutes) is capable of reliably assessing the current status of your system.* Automatic PD detection during normal mains operation (without switching off the cable route)* With DeCIFer technology: PD identification based on 500 million measurement results* Precise online PD mapping with PD transponder
-
Mess- & Prüfsysteme GmbH
The Transformers and measurement capacitors used in high voltage and Partial Discharge test equipment are typically reliable over several decades of continious use. The control technology is however typically obsolete after only 10-15years. MPS offers automated , state-of-the-art High Voltage Testing Equipment with the following features.
-
VLF Series -
High Voltage Inc.
VLF hipots perform voltage withstand tests and provide the voltage source for diagnostic cable testing. There is no better method for verifying the AC integrity of a cable than applying VLF AC voltage. Tan delta and partial discharge measurement accessories are frequently purchased along with VLF equipment to extend their capabilities.
-
TECHIMP PD Hub™ -
Techimp HQ S.r.L
Techimp’s Partial Discharge (PD) Monitoring systems usually consists of a Central Unit and distributed Data Acquisition Units – the PD Hub™ - able to acquire and process the PD signals locally detected through PD sensors installed on each of main electrical assets (generator, transformer, HV cables and GIS).
-
PADD -
Amperis sl
We developed the PADD for the detection of internal and external partial discharges on metal oxide lightning rods. Defects can cause radio interference in communication systems or TV images, interference whose origin is very difficult to locate. We have developed a unique technology for detecting radio frequencies for use under voltage.
-
Weshine Electric Manufacturing Co., Ltd
TEV partial discharge inspection instrument uses two emerging technologies, transient-to-ground voltage (TEV) measurement and ultrasonic (US) measurement, to detect faults in switchgear. The equipment is portable and easy to operate. The TEV sensor is attached to the wall of the box, and the US sensor scans and detects along the gap on the switch cabinet.
-
Wuhan Sangao Electrical Test Installations Limit Co.
Inflatable Ultralight Non Partial Discharge Testing Transformer is a high-end testing transformer which firstly marketed in China by our company. The high-light characteristic of the equipment reflects the smallness in size, lighter in weight clean, oil-free, unnecessary static of field investigation, longer working life without maintenance and slightness in non-partial-discharge. It is used for the insulators' voltage-resistance testing.Major technical characteristicVoltage unit50.100.150.200.250.300.500kVCapacity unit3.5.10.15.20.25.30.50.100.150.200.300.500.1000kVAInput voltage220, 380V uniphase 50HzImpedance voltage6%≤No-load current8%≤Wave form distortion3%≤Annual gas leakage1%≤
-
Techimp HQ S.r.L
UHF Spiral antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset. It is a broadband antenna with a flat response which makes Spiral antenna suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain.
-
Leakshooter LKS 1000-V.2 -
Synergys Technologies
1st ultrasonic compressed air, gaz and vacuum leak detector with camera. Specialy dedicated to visualize the spots where compressed air is leaking, the LEAKSHOOTER LKS 1000 – V.2 has many other applications such as : steam trap monitoring, bearing monitoring, electrical applications like partial discharge, corona effects, punctured isolators, electrical tracking detection.
-
PDScope -
Techimp HQ S.r.L
Techimp PDSCope is a brand new product of the PDCheck family particularly designed to suit all the requisites of the Techimp TiSCADA systems for on-line monitoring of diagnostic quantities in electrical assets.Techimp PDSCope is a powerful PD analyzer based on Techimp TF Map technology (patented) allowing preliminary noise rejection and automatic calculation of statistical parameters relevant to Partial Discharges.